The effect of thermal resistance of building’s opaque elements and windows surface on air exchange intensity during the summer season

Dorota Bzowska

Abstrakt

The purpose of this work – connected with overheating process occurring in buildings – was to investigate the intensity of natural air exchange when a value of thermal resistant for outside walls is being increased together with the increase of the window’s surface. To obtain higher thermal resistant the outside partition were covered with insulating material subsequently from 3 to 30 cm. Window surface to wall surface ratio (wwr) was changing from 5% to 50%. The window’s test surface was facing east, south and west in turn while the wwr of the remaining orientations was kept at a constant 1/10 of the wall. The intensity of the buoyancy flux was analyzed as well. Three forms of ventilation airflow were considered – with assisting and opposing winds and no wind appearance. The process was examined in a single zone building, naturally ventilated, fitted with heat accumulating mass.

Słowa kluczowe: thermal resistance, buoyancy flux, natural air exchanger, solar heat gains
References

Bzowska D., Dynamika procesów wymiany ciepła i naturalnej wymiany powietrza w budynkach o różnej strukturze materiałowej przegród, Prace IPPT 2/2007.

Gasparella A., et al., Analysis and modelling of window and glazing systems energy performance for a well insulated residential building, Energy & Buildings 43, 2011, 1030-1037.

Grinning S., et al., Windows in the building of tommorrow: Energy losers or energy gainers?, Energy & Buildings 61, 2013, 185-192.

Haim D., et al., Optymalizacja fasad podwójnych pod kątem ośzczędności energii i środowiska wewnętrznego, Monografia, Wydawnictwo PŁ, 2013.

Kim T., Todorovic M., Tuning control of building glazing’s transmittance dependence on the solar radiation wavelenght to optimaze daylighting and building’s energy efficiecy, Energy & Buildings 63, 2013, 108-118.

Kisilewicz T., Wpływ izolacyjnych, dynamicznych i spektralnych właściwości przegród na bilans cieplny budynków energooszczędnych, Monografia, Wydawnictwo PK, Kraków 2008.

Leskvar V.Z., Premrov M., An approach in archictertural of energy-effcient timber buildings with a focus on the optimal glazing size in the south-oriented façade, Energy & Buildings 43, 2011, 3410-3418.

Li Y., Delsante A., Natural ventilation induced by combined wind and thermal forces, Building and Environment, 36, 2001, 59-71.

Persson M., et al., Influence of window size on the energy balance of low energy houses, Energy & Buildings 38, 2006, 181-188.